Sign In | Join Free | My gimpguru.org
China Dawnergy Technologies(Shanghai) Co., Ltd. logo
Dawnergy Technologies(Shanghai) Co., Ltd.
Help people better connected through fiber
Verified Supplier

6 Years

Home > Outdoor Fiber Optic Cable >

SM 24 Aerial Duct Application Optical Fiber Cable

Dawnergy Technologies(Shanghai) Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

SM 24 Aerial Duct Application Optical Fiber Cable

Brand Name : DAWNERGY

Model Number : GYTA

Certification : CE/TELCORDIA

Place of Origin : CHINA

MOQ : 100KM

Payment Terms : T/T, L/C, D/A, D/P

Supply Ability : 10,000KM PER DAY

Delivery Time : 10-20 work days

Packaging Details : Wooden DRUM

Product : SM 24 AERIAL OR DUCT APPLICATION OPTICAL FIBER CABLE

Fiber : SM 24

Total unit count : 4LT+1FR

Application : Duct and Aerial

sheath thickness : 1.7mm

Loose tube diameter : 1.8mm

Steel wire diameter : 1.4mm

Contact Now

SM 24 AERIAL OR DUCT APPLICATION OPTICAL FIBER CABLE

Cable Cross-section

SM 24 Aerial Duct Application Optical Fiber Cable

Cable Identification

Fiber color code

SM 24 Aerial Duct Application Optical Fiber Cable

Loose tube (LT) & filler rod (FR) color code

SM 24 Aerial Duct Application Optical Fiber Cable

* “LT” means “Loose Tube”;

** “FR” means “Filler Rod”.

Cable Assembly & Dimensions

Fiber

count

Max. fiber count

per tube

Loose tube diameter Steel wire diameter

Total unit

count

(LT + FR)

sheath thickness

(nominal*)

Overall diameter

(nominal**)

Weight

(approx.)

mm mm mm mm kg/km
24 6 1.8 1.4 4LT+1FR 1.7 9.7 80

* The nominal sheath thickness may have a tolerance with ±0.1mm.

* * The nominal overall diameter may have a tolerance with ±0.2mm.

Performance of Cabled Optical Fiber

The performance of cabled optical fiber (ITU-T Rec. G.652D)

Item Specification
Fiber type Single mode
Fiber material Doped silica

Attenuation coefficient

@ 1310 nm

@ 1550 nm

£ 0.36 dB/km

£ 0.22 dB/km

Cable cut-off wavelength £ 1260 nm
Zero-dispersion wavelength 1300 ~ 1324 nm
Zero-dispersion slope £ 0.092 ps/(nm2.km)

Chromatic dispersion

@ 1288 ~ 1339 nm

@ 1271 ~ 1360 nm

@ 1550 nm

@ 1625 nm

£3.5 ps/(nm. km)

£5.3 ps/(nm. km)

£18 ps/(nm. km)

£22 ps/(nm. km)

PMD £0.2 ps/km1/2
Mode field diameter @ 1310 nm 9.2±0.4 um
Core / Clad concentricity error £ 0.6 um
Cladding diameter 125.0 ± 0.7 um
Cladding non-circularity £0.6%
Primary coating diameter 245 ± 5 um

Performance of Optical Fiber Cable

Cable bending radius: 10 x cable diameter (static)

20 x cable diameter (dynamic)

Application temperature range

Operating temperature range : -40oC to +70oC
Storage / Transport temperature range : -40oC to +70oC
Installation temperature range : -10oC to +60oC

Mechanical & environmental performance test

S/N Item Test Method Acceptance Condition
1

Tensile Strength

IEC 60794-1-E1

- Load: 1.5KN

- Length of cable under load: 50 m

- load time: ≥1min.

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

2

Crush Test

IEC 60794-1-E3

- Load: 1.0KN/100mm

- Load time: ≥1min.

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

3

Impact Resistance

IEC 60794-1-E4

- Points of impact: 3

-Times of per point: 1

- Impact energy:4.5NŸm

- Radius of hammer head: 12.5mm

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

4

Repeated Bending

IEC 60794-1-E6

- Bending radius: 20 x cable diameter

- Load: 150 N

- Flexing rate: 3 sec/cycle

- No. of cycle: 30

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

5

Torsion

IEC 60794-1-E7

- Length: 1 m

- Load: 150 N

- Twist rate: 1 min/cycle

- Twist angle: ±90°

- No. of cycle: 10

- Loss change £ 0.1 dB @1550 nm

- No fiber break and no sheath damage.

6

Water Penetration Test

IEC 60794-1-F5B

- Height of water: 1 m

- Sample length: 3 m

- Test time: 24 hours

- No water shall have leaked from the opposite end of cable.
7

Temperature Cycling Test

IEC 60794-1-F1

- Temperature step:

+20oC→-40oC→+70C →+20oC

- Time per each step: 12 hours

- Number of cycle: 2

- Loss change £ 0.05 dB/km@1550 nm

- No fiber break and no sheath damage.

8

Compound Flow

IEC 60794-1-E14

- Sample length: 30 cm

- Temp: 70°C ± 2°C

- Time: 24 hours

- No compound flow

Packing

6.1 Each single cable length been wound on an iron stand-wooden composite or pure wooden drum.

6.2 Covered by plastic buffer sheet.

6.3 Sealed by strong wooden battens.

6.4At least 1m of cable inner end should be reserved for testing.

SM 24 Aerial Duct Application Optical Fiber Cable

Note: The value “D” contain the seal dimension

Cable Type Drum length D d B b
GYTA m mm mm mm mm
24F 4000 1180 450 680 630

SM 24 Aerial Duct Application Optical Fiber Cable


Product Tags:

SM 24 Aerial Optical Fiber Cable

      

SM 24 Duct Optical Fiber Cable

      

Doped silica Cabled Optical Fiber

      
Quality SM 24 Aerial Duct Application Optical Fiber Cable wholesale

SM 24 Aerial Duct Application Optical Fiber Cable Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Dawnergy Technologies(Shanghai) Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)